Pneumatics & Hydraulics
Compressor capacity (pump-up) test
Measure real compressor output from receiver fill time.
Calculating…
How it's calculated
FAD = V × (P2 − P1) ÷ (P_atm × t)
With all air users isolated, time how long the compressor takes to raise the receiver pressure between two points. A result well below the rated output points to worn elements, a slipping belt, a blocked intake filter or an inlet valve problem.
Include the volume of the pipework, and make sure nothing is using air during the test.